lemon-mirror:
Home >> Hyundai >> 2001 >> Accent GL L4-1.6L >> Repair and Diagnosis >> Specifications >> Electrical Specifications >> Charging System >> System Specifications

System Specifications

Generator Type Battery Voltage Sensing
Rated Output 13.5 Volts @ 80 Amps
Voltage Regulator Electronic Built-in Type
Regulating Voltage 14.4 +/- 0.3 Volts
Temperature Compensation -10 +/- 3mV/deg. C