MEASUREMENT STANDARD SERVICE LIMIT
Output Amperage 130 Amps
13.5 Volts at normal engine temperature
Coil (rotor) resistance 2.9 k Ohms
At 68 deg.F (20 deg. C)
Slip Ring O.D. 14.4 mm (0.57 in) 14.0 mm (0.55 in)
Brush Length 10.5 mm (0.41 in) 1.5 mm (0.06 in)