lemon-mirror:
Home >> Chevrolet >> 2001 >> Impala V6-3.8L VIN K >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Testing and Inspection >> Scan Tool Testing and Procedures >> Scan Tool Data, Normal Values and Definitions >> Scan Tool Data Definitions - Powertrain Systems >> EGR Flow Test Count

EGR Flow Test Count

The scan tool range is 0-255. Indicates the number of EGR flow test samples collected during the current ignition cycle. The maximum number of samples allowed is 1 during normal operation. If the PCM battery feed has been disconnected or a DTC P0401 has been cleared, several EGR flow test samples will be allowed during the next ignition cycle. This is to allow repair verification during a single ignition cycle.